T-Roof YAP 2200
Polyester core coated with SBS bitumen and a surface sprinkled with sand. Adhesive edges of bitumen with protective film that is removed during installation
Strong roofing underlay
UV-protected for up to 3 months
Down to 1.5° (approx. 1:40) roof pitch
Application Area
The product is intended as an roofing underlay on a solid wood base. For surface layers such as roofing felt, shingles, profiled sheet metal, and roof tiles. The surface layer dictates but the minimum slope is 1.5° (approx. 1:40) for exposed but not battened roofs. For battening and exposure without outer roof covering, a minimum of 14° (1:4) applies! If battening is needed at a slope below 14° (1:4), it should be done directly in conjunction with the installation of the outer roof. For the minimum thickness of the base's wood panel, see table AMA Hus-21, HSD.1331/1. For battened outer roofs, at least 20 mm clapboard wood panel, and for non-battened, at least 23 mm.
Installation
Preparation:
Installation is done with strips across the direction of the roof slope. Rolling is done from right to left so that the side inside the roll becomes the top side when unrolled. The strips are easiest laid from the bottom and with overlapping subsequent upwards. The substrate should be dry, even, and stable to avoid deflection and movements.
Nailing and seam gluing:
Mechanical fastening should be with hot-dip galvanized roofing felt nails at least 25 x 2.5 mm. The fastening can be concealed in the upper adhesive edge of the lower sheet. The overlapping sheet is adjusted, fastened, and the protective film on the adhesive edges is removed. Then the overlap is pressed together so that the fastening remains hidden. Alternatively, the fastening can be exposed.
In case of any transverse joints, approved roofing felt adhesive is used. For more detailed installation instructions and other detailed solutions, see the separate installation guide (included with each roll and available in digital format on the website).
Important!
- For open and visible fastening, consider roof slopes <14° (<1:4) as the roofing underlay may be exposed to precipitation and/or if the outer roofing is not installed immediately. Coat the nailing with Sealant K-36 or equivalent repair compound for bitumen waterproofing.
- When covering flat roof tiles, the supplier's guidelines for the underlay must be followed! For unprofiled roof tiles or in wind-exposed areas (coastal), it is recommended to choose a more secure underlay such as T-Roof Epic or roofing underlay such as T-Roof YEP 2500.
- For concealed fastening, carefully check the strength of the joint after installation. Consider adverse weather conditions and ensure any temporary securing of overlaps or protective covering until the permanent surface layer is installed!
- The adhesive edges have aggressive adhesion under normal conditions! In cooler weather (<+10°C), there may sometimes be a need to improve adhesion. Use a heat gun and gently warm the adhesive surfaces. Press the seam together carefully! In cool weather, rolls should be pre-stored for at least 1 day in a warm storage.
- Be mindful to gently load the surface and immediately repair any damage with roofing felt adhesive Sealant K-36 or equivalent repair compound for bitumen waterproofing. For larger damage, use and attach/glue a strip from the roofing underlay.
- Mechanical fastening should be hot-dip galvanized roofing felt nails, minimum 25 x 2.5 mm.
- Always cover with the surface layer (tiles, metal sheets, etc.) as soon as possible to avoid exposure to sunlight and adverse weather conditions. During construction, the roofing underlay can be exposed to sunlight for a maximum of three months. In the operational stage, the underlay should be protected by the outer roof covering.
- Rolls should be stored upright on a flat, dry surface and protected from sun and precipitation.
- T-Roof YAP 2200 is diffusion-tight and when mounted on a wooden substrate, the space underneath should be ventilated according to standard practice.
Articles
- Name Art.nr Specification
Technical specification
- Weight (approx): 2200 g/m²
- Thickness: approx. 1.7 mm
- Coverage area: 9.2 m²
- Roll dimension: 1 x 10 m²
- Surface coverings: Fine sand
- Asphalt: SBS bitumen
- Core: Polyester core
- Roll weight: approx. 22 kg
- Aging resistance: Good
- Waterproofness: Sealed/W1
Accessories for T-Roof YAP 2200
Related Products
Do you need help or have questions about our products?
Try our chatbot
Our chatbot Tea is based on AI and has been trained on all the information available on the website. You can find Tea at the bottom right corner.
Search among questions and answers
We often receive many interesting questions, and we have compiled the most common ones in one place.
Contact our staff
If you need to talk to us, we are of course also available by phone or email!